Setting the pressure – Retrotech DM-2A User Manual

Page 39

Advertising
background image

Retrotec Energy Innovations, Ltd.

31

DM-2A Mark II 2008-02-22

9. Press the J

Og

/H

Old

keypad button again. Notice that Hold now appears at the top

centre of your gauge display screen (as shown next). In this state, your gauge will
hold the current measurements. This is useful when you wish to freeze a specific
pressure reading at a given speed.

10. Press the J

Og

/H

Old

keypad button a third time to cycle the feature to off, as indicated

on your display screen.

11. To turn the test device fan off, press the S

et

S

peed

keypad button, enter a percent

value of 0 and press the e

nteR

keypad button. Your test device fan will gradually slow

to a stop.

Setting the Pressure

12. Press the S

et

p

ReSSuRe

keypad button. Notice that the words Room Pressure: now

appear on the gauge display screen followed by a blinking cursor (as shown next).
This feature enables you to manually control the pressure of a room or enclosure
using the pressure created by the test device fan.

DM-2A Mark II Dual-Channel Pressure Gauge