SECTION 2: INSTALLER RESPONSIBILITY

The installer is responsible for the following:

• To install the heater, as well as the gas and

electrical supplies, in accordance with applicable
specifications and codes. Roberts-Gordon LLC
recommends the installer contact a Local
Building Inspector or Fire Marshal for guidance.

• To use the information given in a layout drawing

and in the manual together with the cited codes
and regulations to perform the installation.

• To install the heater in accordance with the

clearances to combustibles.

• To furnish all needed materials not furnished as

standard equipment.

• To plan location of supports, vents and air

intakes.

• To provide access for servicing.

• To provide the owner with a copy of this

Installation, Operation and Service Manual.

• To never use heater as support for a ladder or

other access equipment and never hang or
suspend anything from heater.

• To ensure there is adequate air circulation

around the heater and to supply air for
combustion, ventilation and distribution in
accordance with local codes.

• To provide a method that ensures that the air flow

through the heat exchanger is within the
acceptable range indicated on the rating plate
prior to energizing the heater, and that such air
flow continues at least 90 seconds after the
heater is de-energized.

• To ensure the heater is placed in an approved

application.

2.1 Wall Tag

A laminated wall tag is included with the heater as a
permanent reminder of the safety instructions and
the importance of the required clearances to
combustibles. Affix the tag by peeling off the backing
of the adhesive strips on the rear surface and
position the tag on a wall near the heater.

A copy of the wall tag (P/N 91039831) is illustrated
on the back cover.

Know your model number. Model number is found
on the heater and throughout the Installation,
Operation and Service Manual.

2.2 Corrosive Chemicals

Roberts-Gordon LLC cannot be responsible for
ensuring that all appropriate safety measures are
undertaken prior to installation; this is entirely the
responsibility of the installer. It is essential that the
contractor, the sub-contractor, or the owner
identifies the presence of combustible materials,
corrosive chemicals or halogenated hydrocarbons*
anywhere in the premises.

* Halogenated Hydrocarbons are a family of chemical
compounds characterized by the presence of halogen
elements (fluorine, chlorine, bromine, etc.). These com-
pounds are frequently used in refrigerants, cleaning
agents, solvents, etc. If these compounds enter the air
supply of the burner, the life span of the heater compo-
nents will be greatly reduced. An outside air supply must
be provided to the burners whenever the presence of
these compounds is suspected. Warranty will be invalid
if the heater is exposed to halogenated hydrocarbons.

2.3 National Standards and Applicable Codes

All appliances must be installed in accordance with
the latest revision of the applicable standards and
national codes. This refers also to the electric, gas
and venting installation. Note: Additional standards
for installations in public garages, aircraft hangars,
etc. may be applicable.

CAUTION

Product Damage Hazard

Do not use heater in area containing
corrosive chemicals.

Refer to appropriate Material Safety Data
Sheets (MSDS).

Failure to follow these instructions can result
in product damage.