SECTION 15: R

EPLACEMENT

P

ARTS

39 of 47

SECTION 15: REPLACEMENT PARTS

See warnings and notes

on Page 31, Section 13

before removing or replacing parts

Burner Components
All serviceable burner parts are accessed by the
door on the side of the heater. Remove the
sheetmetal screws.

15.1 Gas Valve

Remove the gas supply pipe at the heater inlet.

Follow steps on

Page 40, Section 15.2 through

Page 40, Section 15.2.1 to remove gas valve/
manifold.

Replace in reverse order. Verify that the gas flow
direction of the valve is correct. Use a minimum
amount of gas seal on the thread joint. Check that
all the joints are leak free. Reset gas valve.

See

Page 28, Section 11.2.2.

IT IS IMPORTANT THAT ONLY THE CORRECT
GAS VALVE IS USED WHEN REPLACING THESE
CONTROLS.

.

Carbon Monoxide Hazard

WARNING

Use only genuine ROBERTS GORDON

®

replacement parts per this installation, operation and

service manual.

Failure to follow these instructions can result in death, electric shock, injury or property damage.

Explosion Hazard

DANGER

Electrical Shock Hazard

Fire Hazard

½PSI

IN

C

ON

OFF

Flexible Air Duct

NOTE: Separated combustion

Description

Part Number

Gas Valve, NG (Models UHD[X][S] 75 - 125)

90032505

Gas Valve, LP (Models UHD[X][S] 75 - 125)

90032506

model shown.