Roberts Gorden 125 User Manual

Page 33

Advertising
background image

SECTION 10: W

IRING

25 of 47

10.5 Electrical Connection to the Heater

IMPORTANT: Junction box is not provided with heater.
Conduit can also be attached directly to heater with wire junction made within the heater cabinet.

BX Connector

Junction Box

Flexible Conduit

Burner

Connect wires together

with suitable approved

wire connectors.

Green to Ground

White to L2

Black to L1

L1
L2

Ground

Black

White

Green

Advertising
This manual is related to the following products:

75, 100