Renesas SH7641 User Manual

Page 709

Advertising
background image

Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 659 of 982

REJ09B0023-0400

(16) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is

Restarted in Phase Counting Mode

Figure 18.100 shows an explanatory diagram of the case where an error occurs in PWM mode 2
and operation is restarted in phase counting mode after re-setting.

1

RESET

2

TMDR

(PWM2)

3

TIOR
(1 init

0 out)

5

TSTR

(1)

4

PFC

(MTU)

6

Match

7

Error

occurs

8

PFC

(PORT)

9

TSTR

(0)

10

TMDR
(PCM)

11

TIOR
(1 init

0 out)

12

PFC

(MTU)

13

TSTR

(1)

• Not initialized (cycle register)

High-Z

High-Z

MTU module

output

TIOC*A

TIOC*B

Port output

TIOC*A/PTE[n]

TIOC*B/PTE[n]

n = 0 to 15

Figure 18.100 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode

1 to 9 are the same as in figure 18.97.

10. Set phase counting mode.

11. Initialize the pins with TIOR.

12. Set MTU output with the PFC.

13. Operation is restarted by TSTR.

Advertising
This manual is related to the following products: