Renesas SH7641 User Manual

Page 718

Advertising
background image

Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 668 of 982

REJ09B0023-0400

(25) Operation when Error Occurs during Complementary PWM Mode Operation, and

Operation is Restarted in Reset-Synchronous PWM Mode

Figure 18.109 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in reset-synchronous PWM mode.

1

RESET

2

TOCR

3

TMDR

(CPWM)

5

PFC

(MTU)

4

TOER

(1)

6

TSTR

(1)

7

Match

8

Error

occurs

9

PFC

(PORT)

10

TSTR

(0)

11

TMDR

(normal)

12

TOER

(0)

13

TOCR

14

TMDR

(RPWM)

15

TOER

(1)

16

PFC

(MTU)

17

TSTR

(1)

High-Z

High-Z

High-Z

MTU module

output

TIOC3A

TIOC3B

TIOC3D

Port output

TIOC3B/PTE[6]

TIOC3A/PTE[7]

TIOC3D/PTE[4]

Figure 18.109 Error Occurrence in Complementary PWM Mode,

Recovery in Reset-Synchronous PWM Mode

1 to 10 are the same as in figure 18.105.

11. Set normal mode. (MTU output goes low.)

12. Disable channel 3 and 4 output with TOER.

13. Select the reset-synchronous PWM mode output level and cyclic output enabling/disabling

with TOCR.

14. Set reset-synchronous PWM.

15. Enable channel 3 and 4 output with TOER.

16. Set MTU output with the PFC.

17. Operation is restarted by TSTR.

Advertising
This manual is related to the following products: