Renesas SH7641 User Manual

Page 833

Advertising
background image

Section 20 USB Function Module

Rev. 4.00 Sep. 14, 2005 Page 783 of 982

REJ09B0023-0400

(1) Transition from normal operation to stall

(1-1)

(2) When transaction is performed when internal status bit is set, and Clear Feature is sent

(2-1)

STALL handshake

Transaction request

STALL handshake

(2-2)

Clear Feature command

(3) When Clear Feature is sent before transaction is performed

(3-1)

1. In case of USB

specification
violation, etc., USB
function module
stalls endpoint
automatically

1. Transmission of

STALL handshake

1. Internal status bit

cleared to 0

2. USBEPSTL not

changed

1. USBEPSTL cleared

to 0 by application

2. IN/OUT token

received from host

3. Internal status bit

already set to 1

4. USBEPSTL not

referenced

5. Internal status bit

not changed

Normal status restored

Internal status bit

0

→ 1

USBEPSTL

0

Internal status bit

1

USBEPSTL

0

Internal status bit

1

USBEPSTL

0

Internal status bit

1

→ 0

USBEPSTL

0

Stall status maintained

To (2-1) or (3-1)

Figure 20.14 Automatic Stall by USB Function Module

Advertising