Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 681 of 982

REJ09B0023-0400

18.9.4 Operation

Input Level Detection Operation: If the input conditions set by the ICSR1 occur on any of the
POE0 to POE3 pins, all high-current pins become high-impedance state. However, only when the
general input/output function or MTU function is selected, the large-current pin is in the high-
impedance state.

1. Falling Edge Detection:

When a change from high to low level is input to the

POE0 to POE3 pins, all high-current pins

become high-impedance state. Figure 18.115 shows the timing example for the

POE0 to POE3

pins which enters the high-impedance state through input of a change from high to low level.

POE input
(0 to 3)

P

φ rising

P

φ

TIOC3B/
PTE[6]

Note: Other high-current pins (TIOC3D/PTE[4], TIOC4A/PTE[3], TIOC4B/PTE[2], TIOC4C/PTE[1], TIOC4D/PTE[0]) also
become the Hi-Z state at the same timing.

Falling edge detected

Hi-Z state

Figure 18.115 Falling Edge Detection Operation