Installing the water heater, Branch circuit sizing and wire size guide, Customer approval – Rheem RS80-42BP User Manual

Page 14

Advertising
background image

14

Installing the water heater.

Review the checklist for installation requirements.

Check the following before beginning installation.

Permits

Obtain required permits before installation.

Work Force

An 80 gallon storage tank weighs up to 242 lbs
empty, requiring a crew of two or more to install.

Inventory

Review Section on Frames, included hardware, and
all optional supplies before beginning installation.

Required Tools, Equipment and Supplies

Basic Plumbing, Electrical and Carpentry Supplies

• Metric wrench (36 mm open end wrench)

• 12” pipe wrench

• Two 12” adjustable (crescent)

• Wrenches

• Water pressure gauge

• Crowbar

• Copper tubing cutter

• Soldering kit

• Caulking gun

• 24” Spirit (bubble) level

• Cable cutter / stripper

• 6” diagonal cutting and long nose pliers

• 100' Grounded extension cord

• Screwdriver Set (# 2 Philip’s, 1/4” Slotted)

• Tape measure (100 Foot)

• 16-Ounce claw hammer

• Marking pen

• Utility knife

• 3/8”-drive socket set

• 2 Extension ladders

• Flashlight / electric lantern

• Pipe vice / cutter / threader

• Volt, ohm, ammeter

• Hacksaw

• 1/2” Electric drill with bit set

• Skill Saw with standard and masonry blades

• Crane, if required

• 1” Wood-boring bit

Consumable Supplies:

• Masking/duct tape

• Wood/sheet metal screws

• Dielectric pipe unions

• Waterproof sealing compound

• 5/16” Lag Screws, 1 3/4”, 2”, 3”, 6”, as required

• Washers

• Nails, 16g, or assorted, as required

• Silicone sealant

• 2' x 4' x 8'4” redwood, treated-wood or

• Unistrut runners, as required

NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code.
Refer to the wiring diagrams in this manual for field wiring connections.

Branch Circuit Sizing and Wire Size Guide

Total Water

Recommended Over Current Protection

Copper Wire Size AWG Based

Heater Wattage

(fuse or circuit breaker amperage rating)

on N.E.C. Table 310-16 (75°C)

208V

240V

277V

480V

208V

240V

277V

480V

3,000 or lower

20

20

15

15

12

12

14

14

4,000

25

25

20

15

10

10

12

14

4,500

30

25

25

15

10

10

10

14

• Review the checklist with the customer

and discuss all installation
requirements and procedures.

• Ask the customer to sign the checklist.

Customer Approval

Advertising