Installing the water heater, Types of roof installation – Rheem RS80-42BP User Manual

Page 18

Advertising
background image

18

Installing the water heater.

Types of Roof Installation

Installation types are divided into the
following:

Standard Installation:
The system is mounted to wood or
Unistrut runners directly to the roof
with no need for pitch or directional
changes.

Metal / Sturdy Tile Installation:
The system is mounted directly to the
roof with no need for pitch or
directional changes.

Frame Installation
(Side, Reverse, Shallow-Pitch and
Flat-Roof Installation)
The system is mounted on a variable
pitch frame to provide pitch or a fixed
pitch frame to provide directional
changes.

This section contains instructions for correct installation of the system. Complete the procedures in the
order listed.

NOTICE: Installation
of roof supports,
plumbing, and
electrical components
must conform to local
codes.

Plumbing System Schematic for Installation as Pre Heater

3/4”

3/4”

Collector

M = Mixing Valve
T/P = Temperature & Pressure Relief

T/P

Collector

Valve Settings:
Solar Only = (TWV1-1) + (TWV2-1) + (Pre Heat OFF)
Storage Only = (TWV1-2) + (TWV2-2) + (Pre Heat OFF)
Solar Pre Heat = (TWV1-1) + (TWV2-2) + (Pre Heat ON)

TWV1 = Two Way Valve - 1 Inlet Selector
TWV2 = Two Way Valve - 1 Outlet Selector
Pre Heat = Solar Pre Heat Valve

Notice: All pipe work 3/4” unless

otherwise stated.

Advertising