Rheem RS80-42BP User Manual

Page 17

Advertising
background image

17

Plumbing System Schematic for Replacement of Existing Electric Water Heater

Tank

3/4”

3/4”

Plumbing System Schematic for Installation of stand alone Water Heater

Valve Settings:
Solar Only = (TWV1-1) + (TWV2-1) + (Pre Heat OFF)
Storage Only = (TWV1-2) + (TWV2-2) + (Pre Heat OFF)
Solar Pre Heat = (TWV1-1) + (TWV2-2) + (Pre Heat ON)

TWV1 = Two Way Valve - 1 Inlet Selector
TWV2 = Two Way Valve - 1 Outlet Selector
Pre Heat = Solar Pre Heat Valve

Tank

3/4”

Collector

Collector

Collector

Collector

3/4”

M = Mixing Valve
T/P = Temperature & Pressure Relief

T/P

T/P

M = Mixing Valve
T/P = Temperature & Pressure Relief

Advertising