Collector Installation

Collector Union

Collector Union

Collector Nut

Fill

Assembly

Collector

Nut

Collector

Plug

Collector Fitting Installation Detail

1. Set collectors in place, resting lower

ends on collector extrusion or frame,

2. Remove plugs from corners of the

collectors

3. Connect collectors with collector

unions. Do not tighten fully (refer to
points A & B in the figure above).

4. Check that collectors slope 1/2” per

collector from horizontal (hot pipe
side to be higher).

6. Install the collector plug and the

collector nut at Point C.

7. Install collector fill assembly and

collector nut at Point D.

8. Attach collectors to support

structure as shown below.

Standard Installation

Attach collectors to extrusion using
2 sets of collector clamps, screws and
nuts, per collector .

Frame Installation

1. Attach collectors with 2 sheet metal

screws per collector, through the
angle iron upright into the collector
frame at the top and bottom of each
collector.

2. Tighten collector unions, parts and

hardware securely.

3. Continue with storage tank

installation.

CAUTION: The

Extrusion must slope
1/2” per collector
from horizontal (hot
pipe side to be higher)
for the system to work
correctly.

!

CAUTION: Do

not damage Internal
Collector Absorber
with screws.

!

Collector Attachment Details:
Standard, Metal, or Tile.

Collector Attachment Details:
Frame Installation

Advertising