Troubleshooting Tips
Save time and money! Review the chart on this page
first and you may not need to call for service.

Problem

Possible Causes

What To Do

No Hot Water

Hot water tempering valve

Repair/replace as necessary

fouled

Pressure imbalance (over 5 psi) Locate and repair cause of imbalance.
between hot and cold water lines

Fouled pressure regulator valve Repair/replace as necessary

Cold water line blocked

Repair as necessary.

Low Hot Water

Fouled pressure limiting Valve

Repair/replace as necessary

Pressure

Strainer

Water too Hot

Tempering valve malfunction

Repair/replace as necessary.

System oversized for customer

Cover a solar collector/contact installer.

requirements

Gas coming from Hot

Result of system operating

Run tap to allow gas to escape.

Water tap

but water not being used
Corroded Anode

Replace

CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostats, heating

elements or other safety devices. Refer repairs to qualified service personnel

.

!