Installing the water heater.

• Rectify leakage if

observed at any of the
connections and repeat
steps indicated on
previous page.

• Release the pressure

from the closed loop
by loosening the
PR6 valve from the
Test Block.

• When the pressure is

zero, tighten the
PR6 Jacket Relief Valve.

• Once again remove

the Fill Plug from the
Fill Assembly and
connect the hose.

• Remove the PR6

Jacket Relief Valve
and siphon the entire
contents of the blue
Hartgard container
with help of the hose.

• Water will flow

through the PR6
port on the Test
Block during this
operation.

• When the Hartgard

container is
completely empty,
refit the PR6 valve
onto the Test Block.

• Remove the hose from

the Fill Assembly.

• Allow the fluid to flow

until it stops.

• (This checks the

vacuum seal on the
PR6 valve).

• Once the flow stops,

screw in the Fill Plug.

• Pressurize the Closed

Loop to 11.6 psi as
before with the help of
the bicycle pump and
ensure there is no leak
at the Fill Assembly.

• Ensure that the pressure

remains at 11.6 psi for
at least 10 minutes, as
before.

• Release the pressure

from the closed loop
by removing the PR6
Valve from the Test
Block.

• Remove the Test

Block from the Tank.

• Fit the PR6 Valve in

its place on the tank
after ensuring that the
“O” ring is in its seat.