Auxiliary pump – plumbing connections, Auxiliary pump – Rheem Water Heater User Manual

Page 50

Advertising
background image

AUXILIARY PUMP

50

AUXILIARY PUMP – PLUMBING CONNECTIONS
The auxiliary pump is to be installed:

on the solar cold pipe from the solar storage tank to the solar collectors.

Refer to the label on top of the storage tank to identify the solar cold pipe.
The solar cold pipe connection is located toward the outer edge of the top of
the solar storage tank.

within 1 m of the top of the solar storage tank.

with the inlet and outlet in a vertical orientation.

Note: The arrows on the rear face of the pump indicate the direction of flow
and should be pointing upwards when the pump is in the installed position.

with the mounting bracket securely fixed to a structure, such as a wall, with
suitable screws or anchors.

wired to the control board and earth connector strip (refer to

“Auxiliary Pump

– Electrical Connection”

on page 52).

with the speed setting set on 3.

This speed setting must not be adjusted. The solar control unit automatically
controls and adjusts the speed of the pump to maximise solar contribution.
Manual adjustment of the speed dial setting may result in the system not
operating correctly or efficiently.

enclosed within the mounting cover provided in the kit to protect it from rain
as the pump is not weatherproof.

The mounting cover is to be secured to the mounting bracket with the
screws provided.

with the insulation on the solar cold pipe fitted up to the connections of
the auxiliary pump
, as very high temperature closed circuit fluid can flow
from the solar collectors to the solar storage tank under certain conditions.


Refer to the

installation diagram

on page 51.

Advertising