COMMISSIONING

66

tank and remove the valve

(refer to step

6

)

.

18. Add water to top up the level of the closed circuit fluid in the heat

exchanger if required.

To add water to the closed circuit fluid:

ƒ

If not already removed, disconnect the drain line and remove the
spring clip from the solar circuit relief valve at the top of the solar
storage

War

when r

ning:

emo

so

t rel

as

n d

of

rise

po

be

ce

disc

ill

ƒ

ƒ

n the solar storage tank.

ƒ

ƒ

The solar circuit may be under pressure. Take care

ving the

lar circui

ief valve,

a sudde

ischarge

pressu

d hot va ur may

experien d. This

harge w

create a sharp sound of vapour being released.

Place a funnel in the relief valve fitting.

Add water slowly through the funnel until the level of fluid in the hose
is at the desired level as marked o

Note: It may be necessary to undo the compression nut on the solar
hot pipe at the top of the solar storage tank and loosen the pipe work
from the fitting to assist the flow of water into the closed circuit
through the funnel.

Remove the funnel from the relief valve fitting.

Position the solar hot pipe correctly in its fitting and tighten the
compression nut if this has been loosened.