SECTION 7: HEATER INSTALLATION

To ensure your safety and comply with the terms of
the warranty, all units must be installed in
accordance with these instructions.

The gas or the electrical supply lines must not be
used to support the heater.

Do not locate the gas or electric supply lines directly
over the path of the flue products from the heater.

The heater must be installed in a location that is
readily accessible for servicing.

The heaters must be installed in accordance with
clearances to combustibles as indicated on the rating
plate and in this instruction manual.

The minimum and maximum gas inlet pressures
must be maintained as indicated on the rating plate.

Typical installation configurations are shown
on Page 17, Figure 14

.

Expansion and contraction of the tube dictates that
the minimum suspension lengths must be
maintained.See table on Page 17, Figure 14.

WARNING

Severe Injury Hazard

Secure burner to combustion chamber with
nuts and lockwashers.

Hang heater with materials with a minimum
working load of 75 lbs (33 kg).

Failure to follow these instructions can result
in death, injury or property damage.

WARNING

Cut/Pinch Hazard

Wear protective gear during installation,
operation and service.

Edges are sharp.

Failure to follow these instructions can result
in injury.