Error message cause solution – Rena DA615 User Manual

Page 58

Advertising
background image

Error messages and hints

\text\etd\DA615\Error

8.2

DA615 instruction manual

Error message

Cause

Solution

TEST MACRO TOO LONG

The user-defined test
address is too long.

Limit the size of the test
address to 3 Kbytes.

BUFFER OVERFLOW !!

Error in data transfer.

Check connections of the
interface cable.

EPROM ERROR !!

VERIFY FONT

Error in the Flash prom.

Reload the RENA fonts.

EPROM ERROR !!

VERIFY PROG

Reload the program
(firmware).

RAM ERROR !!

VERIFY RAM

Error in RAM.

Arrange for the CPU board
to be replaced by service
personnel.

PROGRAM ERROR !!

MAKE DEFAULT RESET

Error in program
execution.

- Perform a default ini-

tialization (Sect. 5)

- Reload the firmware.

UNPRINTED ADDRESSES !

FINISH THE JOB

Address was not printed to
the end.

Make no changes in
programming mode when
the print job is running!

PIC ERROR

VERIFY CONTROLLER

Error in controller module
that controls the paper
transport.

- Check module PIC 1665.
- Set the paper feed

mechanism properly.

PIC TIME OUT

VERIFY CONTROLLER

PIC STATUS ANSW.

PAPER OUT (PAP)

PIC CALL

PROGRAM ERROR

TIME OUT PIC

WAITING FOR PAPER

PIC CODE

PAPER OUT (PAP)

IBF ERROR

VERIFY CONTROLLER

PIC OBF ERROR

PAPER OUT (PAP)

Advertising