R/C Operation

102

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Selecting the R/C Input Mode

The R/C Input Mode is the factory default setting.

If the controller has been previously set to a different Input Mode, it will be necessary to
reset it to the R/C mode using the serial port and the PC utility. See “Using the Roborun
Configuration Utility” on page 161, a
nd “Accessing & Changing Configuration Parameter in
Flash” on page 133

Connector I/O Pin Assignment (R/C Mode)

When used in R/C mode, the pins on the controller’s DB15 connector are mapped as

described in the table below.

TABLE 16.

Connector pin-out in R/C mode

Pin
Number

Input or
Output

Signal

Description

1 and 9

Output

Output C

2A Accessory Output C

2

Output

RS232 data

RS232 Data Logging Output

3

Input

Ch 1

R/C radio Channel 1 pulses

4

Input

Ch 2

R/C radio Channel 2 pulses

5 and 13

Power Out

Ground

Controller ground (-)

6

Unused

Unused

Unused

7

Unused

Unused

Unused

8

Digital In

R/C: Ch 3 / Ana In 4

R/C radio Channel 3 pulses - (Not available when
encoder module present)

10

Analog in

Ana in 2

Channel 2 speed or position feedback input

11

Analog in

Ana in 1

Channel 1 speed or position feedback input

12

Analog in

Ana in 3

Unused

Pin1

8

15

9

FIGURE 62. Pin locations on the controller’s 15-pin connector