Wiring limit switches without encoders, Effect of limit switches – RoboteQ Dual Channel Digital Motor Controller AX2550 User Manual

Page 75

Advertising
background image

AX1500 Motor Controller User’s Manual

75

Wiring Limit Switches Without Encoders

Wiring Limit Switches Without Encoders

If no encoder is used, the Encoder Module’s inputs can be used to wire limit switches
directly with solely a pull-up resistor as shown in the diagram below.

Effect of Limit Switches

Each pair of limit switches will stop the motion of a given motor in a given direction. This
will have the effect of stopping the motor when a limit is reached while allowing motion in
the other direction, away for that limit.

TABLE 13. Effects of Limit Switches 1 and 2 on Motor 1

SW1

SW2

Motor 1 Fwd

Motor 1 Rev

OFF

OFF

Allowed

Allowed

ON

OFF

Stopped

Allowed

OFF

ON

Allowed

Stopped

ON

ON

Stopped

Stopped

TABLE 14. Effects of Limit Switches 3 and 4 on Motor 2

SW3

SW4

Motor 2 Fwd

Motor 2 Rev

OFF

OFF

Allowed

Allowed

ON

OFF

Stopped

Allowed

SW3

SW4

Encoder Input

GND

5V Out

Ch B In

Ch B In

Ch A In

6

1

2

5

8 - 4

7 - 3

Ch A In

4.7kOhm

4.7kOhm

SW1

SW2

4.7kOhm

4.7kOhm

FIGURE 45. Signals seen by encoder using multi-levels and limit switches

Advertising