Amps limit – RoboteQ Dual Channel Digital Motor Controller AX2550 User Manual

Page 136

Advertising
background image

Serial (RS-232) Controls and Operation

136

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

This parameters selects the various open loop and closed loop operating modes as well as
the feedback method.

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow-

ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop
(default)

1 = A & B mixed speed open loop

2 = A speed open loop, B position

3 = A & B position

4 = A & B separate speed closed loop

5 = A & B mixed speed closed loop

6 = A speed close loop, B position

page 40

page 93

page 81

6:3

Reserved

6

Ch1 Feedback type

0 = Analog

1 = Encoder

page 93

page 81

7

Ch2 Feedback type

0 = Analog

1 = Encoder

Bit

Definition

See pages

3:0

Coarse Amps

0 = 7.5A

1 = 11.25A

2 = 15A

3 = 18.75A

4 = 22.5A

5 = 26.25A (default)

6 = 30A

page 42

7:4

Fine Amps

Mutliply this number by 0.25 and sub-
stract result from the Coarse Amps value

Advertising