RoboteQ Dual Channel Digital Motor Controller AX2550 User Manual

Page 74

Advertising
background image

Installing, Connecting and Using the Encoder Mod-

74

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Using this circuit when the switch is open, a 0V (low-level) output from the encoder goes
through a 1k and 4.7k voltage divider, thus creating a voltage that will never be below 0.8V
at the encoder module’s input.

When the switch is activated, the module’s input is pulled to 0V.

It is recommended that a voltmeter and/or oscilloscope be used to verify that the right volt-
age levels are created as the encoder rotates and the switches activate.

You may also use the Encoder setup/test function in the Roborun utility (see “Encoder
Testing and Setting Using the PC Utility” on page 79
). If the wiring is correct, the counters
should increment/decrement as the motor rotate. The switch indicators should be always
off unless the switches are actually activated.

Encoder

SW1

SW2

Encoder Module

1kOhm

GND

5V Out

Ch A In

Ch A

Ch B

Ch B In

5V

GND

1kOhm

4.7kOhm

4.7kOhm

FIGURE 44. Signals seen by encoder using multi-levels and limit switches

Advertising