Lighting the water heater, For your safety read before operating, Operating instructions – Ruud PowerVent AP14236 User Manual

Page 23

Advertising
background image

Typical Piping Diagram for Combination Potable/Space Heating Installation

Spring loaded check valve in heating unit
hot water supply line and cold water return

line (not supplied with water heater)

NOTE: This check valve is incorporated

in some heating units. Refer to the

installation instructions supplied with

specific heating unit to determine if it is

required.

All water piping shall be insulated in

accordance with Local and State Energy

Code.

Isolation valve in

cold water return line

from heating unit (not

supplied with water

heater)

Nominal 3/4" size mixing or tempering valve

(refer to warning above). Follow mixing or

tempering valve manufacturer’s instructions for

installation of the valve.

Temperature and pressure relief

valve discharge line

Air Handler

Drain valve
(not supplied with
water heater)

Hot water

to space heater

Temperature and Pressure Relief

Valve, tie to location approved by

local code

See diagrams above for proper

pipe application for vertical

or horizontal supply lines.

Isolation valve in hot water supply line

to heating unit (not supplied with water

heater)

3/4" cold water supply

3/4" Tempered

domestic hot water

supply to house.

Gas line to water heater

6” Air Gap

Combustion Air Inlet

Openings

2 Gallon Thermal

Expansion Tank (if

required-not supplied

with water heater)

Air vent

Heat Trap
6” Min.

3/4" Shut-Off Valve (Typ.)

3/4" Check Valve with 1/8" Hole

Pressure Gauge

3/4" Shut-Off Valve (Typ.)

3/4" Shut-

Off Valve

(Typ.)

Hot water coil

All bronze pump.

Check valve

internal in pump.

Air bleed valve.

Water Sample Tap.

T

FAN

ON

OFF

HEAT

COOL

To HVAC Unit.

Electronically controlled pump timer.

Activates every 6 hours for 60 seconds.

Wire to bronze pump.

3/4" HWS & HWR

to Heating Coil.

Minimum of 2'-0" developed length

of 3/4" pipe.

Water Heater drain pan installed in

accordance with the Local and State

Code

Water Heater to be in accordance with

the Local and State Energy Code

Gas Fired

Water Heater

Gas Direct Vent discharge

must comply with Local

and State Codes

Vacuum Relief Valve

(Not Supplied)

If required, install per local codes

and valve manufacturer’s

instructions.

120° to 130°

140°

23

Lighting the water heater.

Before operating this water heater, be sure to read and follow the instructions on the label pictured

below and all other labels on the water heater, as well as the warnings printed in this manual. Failure

to do so can result in unsafe operation of the water heater resulting in property damage, personal

injury, or death. Should you have any problems reading or following the instructions in this manual,

STOP, and get help from a qualified person.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions and use the Use & Care Manual instructions

exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

OPERATING INSTRUCTIONS

AX 4762

TO TURN OFF GAS TO APPLIANCE

If you cannot reach your gas supplier, call

the fire department.

C.

Do not use this appliance if any part has been

under water. Immediately call a qualified in-

staller or service agency to replace a flooded

water heater. Do not attempt to repair the unit!

It must be replaced!

Use only your hand to push in the gas control

buttons. Never use tools. If the control buttons

will not push in, don’t try to repair them, call a

qualified service technician. Force or attempted

repair may result in fire or explosion.

D.

instructions.

This appliance does not have a pilot. It is equipped

with an ignition device which automatically lights

the burner. Do NOT try to light the burner by hand.

A.

BEFORE PUTTING THIS APPLIANCE INTO

SERVICE - Smell all around the appliance

area for gas. Be sure to smell next to the floor

because some gas is heavier than air and

B.

will settle on the floor.

Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppliers

Do not try to light any appliance.

Do not touch any electric switch; do not use

any phone in your building.

WHAT TO DO IF YOU SMELL GAS

9.

10.

Stop! Read the safety information above on

this label.

Set the thermostat to the lowest setting by

pressing the COOLER or HOTTER buttons

at the same time and holding them for (1)

second. Depress the COOLER button until

the WARM indicator light is lit.

Toggle the “ON/OFF” switch located on the

blower assembly to the “OFF” position.

Turn off all electric power to the appliance.

This appliance is equipped with a Hot Surface

Ignition System which automatically lights the

burner. Do NOT open the inner door of this

appliance and try to light the burner by hand!

Wait five (5) minutes to clear out any gas. If you

smell gas, STOP! Follow “B” in the safety inform-

ation above on this label. If you do not smell

gas, go to the next step.

Turn on all electric power to the appliance.

Toggle the “ON/OFF” switch located on the blower

1.

3.

2.

1.

2.
3.

4.

5.

6.

7.

8.

MANUAL

VALVE

TEMPERATURE DIAL

LED INDICATOR LIGHT

VACATION

WARNING

VERY

HOT

WARM

A

B

C

COOLER

HOTTER

assembly to the “ON” position.

Set thermostat to the desired temperature setting
by pressing the COOLER and HOTTER
buttons at the same time and holding them for (1)
second. Depress the HOTTER button until the
desired temperature is/are lit. The preferred start-
ing point for temperature setting is indicated by
on the thermostat.

If the appliance will not operated, follow the

instructions “TO TURN OFF GAS TO APPLIANCE”

and call your service technician or gas supplier.

Turn off all electric power to the appliance if service is to be performed.

Set the thermostat to the lowest setting by first depressing the COOLER and HOTTER buttons at

the same time and holding for 1 second. Depress the COOLER button until only the WARM indicator

light appears.

Toggle the “ON/OFF” switch located on the blower assembly to the “OFF” position.