Safety Precautions

Do turn off manual gas shut-off valve if water heater

has been subjected to over heating, fire, flood,

physical damage or if the gas supply fails

to shut off.

Do Not turn on water heater unless it is completely

filled with water.

Do Not turn on water heater if cold water supply

shut-off valve is closed.

Do Not allow combustible materials such as

newspaper, rags or mops to accumulate near

water heater.

Do Not store or use gasoline or other flammable

vapors and liquids, such as adhesives or paint thinner,

in vicinity of this or any other appliance.

If such flammables must be used, open doors

and windows for ventilation, and all gas burning

appliances in the vicinity should be shut off including

their pilot burners, to avoid vapors lighting.

NOTICE: Flammable vapors can be drawn by air

currents from surrounding areas to the water heater.

If there is any difficulty in understanding or following

the Operating Instructions or the Care and Cleaning

section, it is recommended that a qualified person or

serviceman perform the work.

Operating the water heater.

CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a

long period of time (generally two weeks or more). HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To dissipate such

gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink

before using any electrical appliance connected to the hot water system. If hydrogen is present, there will be an unusual sound

such as air escaping through the pipe as the water begins to flow. Do not smoke or use an open flame near the faucet at the

time it is open.

!

DANGER:

Hotter water

increases the Potential

for Hot Water SCALDS

.

Households with small

children, disabled, or elderly

persons may require a 120°F

or lower gas control

(thermostat) setting to

prevent contact with HOT

water.

Water Temperature Setting

The temperature of the water in the water

heater can be regulated by pressing the

buttons on the front of the gas control

(thermostat).
Safety and energy conservation are factors

to be considered when selecting the water

temperature setting of the water heater’s

gas control (thermostat(s)). The lower the

temperature setting, the greater the savings

in energy and operating costs.
To comply with safety regulations, the gas

control (thermostat) was set at its lowest

setting before the water heater was shipped

from the factory. The recommended

starting point temperature is 120°F.

Water temperatures above 125°F

can cause severe burns or death from

scalding. Be sure to read and follow the

warnings outlined in this manual and on

the label located on the water heater near

the gas control thermostat.
Mixing valves are available for reducing

point of use water temperature by mixing

hot and cold water in branch water

lines. Contact a licensed plumber or

the local plumbing authority for further

information. (See page 4 for more details.)
The chart on the next page may be used

as a guide in determining the proper water

temperature for your home.

24

Operating Procedure

This heater is equipped with a hot surface

ignitor to light the main burner. There is

no pilot light to be lit, but on initial start-

up, it is recommended that the outer door

be removed (leave inner door in place for

safety) to determine if the hot surface ignitor

and main burner are operating properly.

Once filled with water, it is only necessary

to plug the power cord in and make sure the

“ON/OFF” switch located on the blower

assembly is in the “ON” position to put the

water heater into operation. Within seconds

the hot surface ignitor should heat up, then

the gas valve should open and the main

burner ignite. After the main burner ignites,

replace the outer door. If no main burner

flame is established, the gas control will go

through three trials for ignition before going

into a lock-out. A warning light will alert

the user of this lock-out condition. If this

happens, refer to “Troubleshooting Guide.”

TO SHUT OFF WATER HEATER – Turn

switch on the blower assembly to the “OFF”

position.