This water heater must be installed in accordance with these instructions, local codes, utility company

requirements, and/or in the absence of local codes, use the latest edition of the American National

Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,

400 N. Capitol Street NW, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection

Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54.

Location

The water heater should not be located

in an area where leakage from the tank

or connections will result in damage

to the area adjacent to the heater or to

lower floors of the structure.
When such areas cannot be avoided it is

recommended that a suitable catch pan,

adequately drained, must be installed

under the water heater.
The water heater must be centered in

the catch pan.
The catch pan must not restrict air

flow to the combustion air inlet openings

(perforation openings) located around the

lower perimeter of the water heater.
Catch pan kits are available from the store

where the water heater was purchased, or

any water heater distributor.
Make certain the floor underneath the

water heater is strong enough to

sufficiently support the weight of the

water heater once it is filled with water.
A gas fired water heater or any other

appliance should not be installed

in a space where liquids which give off

flammable vapors are to be used or stored.

Such liquids include gasoline, LP gas

(butane or propane), paint or adhesives

and their thinners, solvents or removers.
DO NOT block or obstruct any of the

combustion air inlet openings located

around the perimeter of the water

heater. A minimum of 1” is required

between these combustion air inlet

openings and any obstruction.
DO NOT obstruct or block the

Flammable Vapor Sensor.
Because of natural air movement in a

room or other enclosed space, flammable

vapors can be carried some distance from

where liquids which give off flammable

vapors are to be used or stored. The open

flame of the water heater’s pilot or main

burner can ignite these vapors and create a

shut down condition of the water heater

which will not allow the water heater

to ignite until examined by a Qualified

Service Technician.

The water heater must be located so it is

not subject to physical damage, for example,

by moving vehicles, area flooding, etc.
If local codes require the use of a stand

kit to raise the water heater 18” above the

floor, please contact the store where the

water heater was purchased, or any water

heater distributor. These kits must comply

with local codes.

The water heater should be installed

so as to minimize the length of plastic

vent pipe and the number of vent

connection fittings required. (Refer to

the “INSTALLATION” Section of this

manual.)

Long hot water lines should be insulated

to conserve water and energy.

The water heater and water lines should

be protected from exposure

to freezing temperatures.

Do not install the water heater in

bathrooms, bedrooms, any occupied

rooms normally kept closed, or in

unprotected outdoor areas.

Minimum clearance from combustible

construction:

If the clearances stated on the

Instruction/Warning Label, located on

the front of the heater differ, install the

water heater according to the clearances

stated on the label.

If the water heater is installed in an

alcove or closet, the entire floor must

be covered by a wood or metal panel.

A minimum of 24” clearance from the

front and top should be available for

adequate inspection and servicing.

The water heater may be installed on

combustible floors, but not directly on

carpeting. If the water heater must be

installed on carpeting, place a metal or

wood panel beneath the water heater,

extending beyond its full width and

depth at least 3” in all directions.

The auxiliary catch pan

installation MUST conform

to local codes.

Diameter of

water heater

plus 2” min.

Max.

2.75

!

WARNING: Combustible

construction refers to

adjacent walls and ceilings

and should not be confused

with combustible or

flammable products and

materials. Combustible

and/or flammable products

and materials should never

be stored in the vicinity of

this or any gas appliance.

Front

Sides

Rear

Top

3”

(7.6 cm)

1”

(2.5 cm)

0”

(0 cm)

12”

(30.5 cm)

7

Notice:

DO NOT

allow

the flammable vapor

sensor to become

submerged in water.

Make sure the catch pan

is properly drained.

Flammable

Vapor

Sensor

Notice:

DO NOT

allow

the catch pan to obstuct

the flammable vapor

sensor.