Replacing the Fusing Unit

21

1

MMMM

Holding the green handle of the
new Fusing Unit, use your other
hand to push the area right in
front of the handle to create a
slight slant, and then push the
Fusing Unit slowly to the back.

Important

❒ Confirm that the Fuser Oil Unit

is facing the inside of the print-
er.

❒ Confirm that the Fusing Unit is

properly positioned in the ma-
chine.

NNNN

Close the upper left cover (

A

A

A

A) and

push the handle (

B

B

B

B) slowly to the

back until it clicks into place.

OOOO

If you removed the External Tray
in step

DDDD

, reattach it to the printer.

Insert the hooks of the External
Tray into the printer slits, and
lower it toward you.

PPPP

If the Duplex Unit is installed,
close the Duplex Reversal Unit.

Reference

See p.2 “Opening and Closing
the Duplex Reversal Unit”

QQQQ

If the 2 Tray Finisher was in-
stalled, reattach the 2 Tray Finish-
er to the printer.

Reference

See p.1 “Detaching the SR770 (2
Tray Finisher)”

RRRR

Plug in the power cable and turn
on the power switch.
The following message appears on
the panel display. Please wait for a
while.

ZDJH050E

ZDJH051J

Please Wait

ZDJH010J

JupP1k_GB_Mainte_F_FM.book Page 21 Thursday, August 22, 2002 4:23 PM