A.2 T-PDS remote programming

The T-PDS can be connected through the Loader port on the S-20LP-station, as well as the
Programmer port on the T2N/T3H CPU module. By using this function, remote
programming/monitoring through S20LP network is available.

(Note 1) T2N must be sellected P/S "ON" with DIP switch 1.

(Note 2) When DIP switch 1 is ON/OFF, T2N is Loader port/Programmer port.

-LP

S20

T2N

-LP

S20

T3H

-LP

S20

T3H

S20LP

STN #3

STN #2

T-PDS

STN #1

To use this function, T-PDS's connection method should be set as "Network".

The screen below is the setting example of T-PDS's connection method for the above
configuration.

Option

Communication (Connection Method)

Setup (Network Setup)

Communication Parameter (Communication Parameter)

<T-PDS Setup options screen>

(Note 1) When connecting on single layer, the Layer 2 Station No. should be set as 0.
(Note 2) The Parity is fixed as even.