NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

1

step 8. The standard Security Chimneys FTF8

roof flashing assemblies include a

storm collar. Slide the storm collar over

outer chimney, rest on flashing spacers

and align with top surface of flashing.

Insert tab in slot, pull tight and bend

tab back over slot. Seal storm collar

to outer chimney with roof caulking or

mastic around entire circumference of

pipe. Also add extra roof caulking to the

tab/slot area to seal completely against

water penetration (Figure 30). Check

all joints very carefully to ensure no

water intrusion can take place.

Roof Ridge

120°

cTd

Termination

chimney

Figure 32

Figure 31

3. Center outer locking section over outer flue

pipe. Push down until locking tabs are firmly

engaged.

4. Pull up slightly on CTD to ensure locking

joint has firmly engaged.

Note: It is recommended that all exterior

exposed metal fireplace components; such as

terminations, flashings, storm collars and/or

flue be painted with a premium quality, high

temperature, rust preventative paint designed

for metal. This is especially important when

installations are made in abnormally adverse

or corrosive environments; such as near lakes,

oceans or in areas with consistently high

humidity conditions. Consult the paint manu-

facturers instructions for proper preparation

and application.

Figure 30

step 9. FTF locking bands, Model FLB, may

be required if the chimney extends

too high above the roof flashing. As

a general rule, if the chimney extends

more than 6' above the roof flashing,

the use of locking bands is advisable

to strengthen the chimney assembly.

Align the locking band at the chimney

joint. Locking bands wrap around pipe

joints equally covering the joints of both

pipe sections. Use the nut provided and

TIGHTEN snugly. Do not overtighten as

this might damage the chimney section

(refer to Figure 25).

Note: If chimney extends more than 8' (2.4 m)

above roof surface, guy wires are also recom-

mended. Use three (3) guy wires, attach to

locking band assembly, extend and secure to

roof in a triangular pattern (Figure 31). Guy wires

are not supplied by the manufacturer.

step 10. using an fTf8-cTd round Termi-

nation:

1. Hold the CTD over top of last chimney section

(Figure 32).

. Center inner slip section in inner flue pipe-

slip down.

mastic

or roof

caulking

locking band