NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

4

Figure 2

assembly ouTlIne

before you start

Check your inventory list to be sure you have

all the necessary parts supplied in good us-

able condition. Check also for any concealed

damage.

Check the operation of the damper. The damper

is controlled through the use of a control lever

located within the firebox opening at the top

center just behind the firebox lintel (Figure 3).

The control lever snaps into place at the extreme

range of motion, up and back in the closed

position. When pulled forward and down, the

damper is open.

Figure 3

locaTIon of fIrePlace

Carefully select the proper location for heat

circulation, aesthetics, chimney obstructions

and clearance to side wall(s). With proper pre-

planning, a slight adjustment of a few inches

can save considerable time and expense later

during construction and assembly.

Figure 4

Carefully consider the position of the fireplace

opening with respect to the location of adjacent

or nearby stairwells, bath or kitchen exhaust

fans and/or return air registers for forced air

furnaces/air conditioners that could cause a

smoking fireplace condition if the house is

tightly insulated.

When locating the fireplace, consideration must

be given to combustibles and final finishing. For

an example of this, see Figure 5 and confine

the final location of combustible finish materials

to the "Safe Zone".

DO NOT permanently place furniture or other

items such as decorative pillows within 60" of

the fireplace front face.

Figure 5 - Clearances

Wall

Covering

Black Portion Of Frame

Not To Be Covered With

Combustible Materials

Safe

Zone

30

°

11-3/8”

18”

Door

Opening

1”

Insulate Joists

Same As Ceiling

Draft Stops

Firestop

CTDT

Termination

Note: Non-

Combustible

Chase

Flashing

Must Be

Used To

Cover

Chase

Opening

Optional

Insulation

In Outside

Walls Of

Chase

8'

Level

Ground Level

damper

closed

damper

open

lintel

warnInG

do not obstruct the collar open-

ings around the base of the chim-

ney at the top of the fireplace.

do not insulate the chase cavity

with blown or fill type insulation

materials.

chimney enclosure

Construct a box-like framed structure to enclose

the fireplace and chimney within the confines

of the manufactured home, not necessarily

above the roof line.

As with all chimney installations, avoid overhead

obstructions such as trees, power lines, etc.

The chimney/fireplace enclosure should be

constructed and insulated just like any outside

wall. In a cold climate, we recommend the base

of the chimney/fireplace enclosure should also

be insulated between the solid continuous floor

beneath the fireplace and the chase bottom.

Insulation in a cold climate installation is not

required for safety.

warnInG

This fireplace and chimney

system is not approved for use

in a bedroom or any room used

for sleeping.

Insulate Joists

Same As Ceiling

Draft Stops

Firestop

CTDT

Termination

Note: Non-

Combustible

Chase

Flashing

Must Be

Used To

Cover

Chase

Opening

Solid

Fireplace

Continuous

Surface

Base

Insulation

(Thermal Barrier)

Note: Local codes may not require firestopping

at the ceiling levels for outside chimney enclo-

sure installations. However, it is recommended

for safety and the reduction of heat loss.

base requirements