Important – TOA Electronics CST38MH User Manual

Page 6

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

6

The safety strips should extend in front and

sides of the fireplace opening 2" (51 mm) . In

the event a wooden support is used to elevate

the fireplace above the floor, a “Z” type safety

strip should be fabricated and used to protect

the front surface of the wood support as well

as the floor beneath the hearth extension (see

Figures 8 and 9). The safety strips should be

tacked down to prevent possible movement.

Note: The “Z” type safety strip is not sup-

plied.

step 3. Refer to fireplace drawings and speci-

fications on Pages 7 and 8 for framing

dimensions and details. False header

may be positioned directly on top of

the fireplace spacers (see Figures 10,

11 and 12).

Figure 9

Figure 8

metal

safety strips

" min.

(51 mm)

Platform

metal

safety strips

*

" min.

(51 mm)

*

*

Figure 10

4 x 6 header

spacer

 x 4 false

header

Figure 12

Figure 11

no combustible

materials in

shaded areas

no

combustible

materials in

shaded areas

If the appliance is to be elevated above floor

level, a solid continuous platform must be

constructed.

The header may rest on the top metal spacers,

but must not be notched to fit around them.

Consult all local codes.

ImPorTanT

under no circumstances can the

fireplace top spacers (Figure

13) be removed or modified,

nor may you notch the header to

fit around or be installed lower

than the spacers. The header

may be in direct contact with

the top spacers but may not be

supported by them.

Advertising