TOA Electronics CST38MH User Manual

Page 8

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

8

Figure 14

framInG wall VarIaTIons

As many as six (6) different framed wall con-

figurations can be constructed to enclose the

Fireplaces. The following illustrations depict

these variations of wall enclosures. Several of

these designs may incorporate book shelves,

wood storage boxes, etc.

Figure 15

framing dimensions for ceiling

Figure 16

csT38mh - wall Types

“c” Type wall

“T” Type wall

“l” Type wall

“h” Type wall

“y” Type wall

Parallel wall

a

b

ceiling framing

c

d

roof framing

framing dimensions for ceiling

Inches (millimeters)

flue Type

a

b

fTf8, Vertical

at " (51 mm)

16 1/"

(419 mm)

16 1/"

(419 mm)

fTf8 offset 30°

at " (51 mm)

16 1/"

(419 mm)

7"

(686 mm)

framing dimensions for roof

Inches

Pitch

fTf8 at 1" (USA)

c

d*

0/1

16 1/"

16 1/"

6/1

16 1/"

19"

1/1

16 1/"

3 1/"

* Perpendicular to roof ridge

step 4. The fireplace should be secured to side

framing members using nailing tabs. Use 8d

nails (Figure 17).

nailing

flange

framing

stud

Note: The nailing tabs are exempt from the

fireplace clearances described on the fireplace

clearance label.

InsTall The combusTIon aIr KIT

(required in Manufactured Home installations)

Outside air drawn into the fireplace supplies

air to the fire for combustion. The outside air
kit (FOAK-6, Cat. No. 90L83) must be installed

before the fireplace is framed and enclosed in

the finished walls.

Install the air intake Collar (provided) as shown

in Figure 18.

There is a one-hand operated shut-off valve

located in the enclosed corner of the fireplace

opening behind the screen. Refer to label for

directions of operation. The combustion air

damper should be fully open when the fireplace

is in operation and fully closed when the fire-

place is not in use to prevent outside air from

entering your home.

Connect the 6” (152 mm) Class 0 or Class 1 air

duct to the outside air collar on the appliance

with the tie strip in the outside air kit (provided).

See Figure 18.

Route the Class 0 or Class 1 air duct out the

back or side wall, up through the ceiling or floor

joists to an outside wall. The air duct should be

located above snow level.

Outside combustion air may be run upwards

or vertically through framing and ceiling joists,

with the hood installed through an outside

wall and 3' (914 mm) below the termination.

Ducting may also be run downward through

floor joists and under the home to a ventilated

crawlspace not considered part of the living

area of the home.

Figure 17