Mechanical disassembly/assembly – Tektronix 1705A User Manual

Page 144

Advertising
background image

Maintenance

1705A Spectrum Monitor

6- 19

Table 6- 7: Test Selectable Components

Circuit Number

Nominal Value

Range of Values

Selection Criteria

R50
R74
R73

5.62K
3.40K
18.2K

2.7K to 8.2K

1K to 6.8K

18K to 27K

To correct nonlin-

earities of L--band

tuners.

R53

115.0K

115K to 130K

To alter magnifier

range when ad-

justment range of

A3R38 is insuffi-

cient.

Mechanical Disassembly/Assembly

Use these instructions for disassembly and reverse them for reassembly, unless
otherwise noted.

WARNING. Before attempting any disassembly/assembly of the instrument, be
sure to disconnect the power cord.

CAUTION. Do not reinsert screws in the rear panel when the instrument is
removed from the cabinet.

NOTE. All screws, unless otherwise noted, are TORXǺ screws and can be
removed with a T15 screwdriver tip (Tektronix part number 003-0966-00). The
exception is #2 Pozidrive

Ǻ screws which can be removed with a #1 PozidriveǺ

tip (003-0443-00).

Do not reinsert screws in the rear panel when the instrument is removed from the
cabinet.

1.

Remove the two bezel screws. See Figure 6-8.

2.

Grasping the bottom of the bezel, pull out and upward. There are two hinges
at the top of the bezel that hold it in place; once the bezel is at an approxi-
mate 45

° angle with the front panel, they will disengage.

Bezel Removal