ASSEMBLY

Assembly Section 2-14

RETURN LINE INSTALLATION

(2004 UPDATE)

The return line will be plumed in next to the pressure line in the tractor remote valve end cap.

Locate the return port and remove the plug (refer to the illustration below and the Parts Section
for the position of the return port). After the plug is removed then install 22mm adapter or elbow.
Next connect a 1/2” hose from the tractor remote valve to the Tiger valve.

(ASM-JD-0213)

LOAD SENSE LINE INSTALLATION - JOYSTICK

(2004 UPDATE)

The load sense line will be plumbed into the side of the tractor remote valve (shown in the

picture on the last page). Install the end cap onto the remote valve as shown. This end cap is a
Tiger custom part to obtain proper operation of the lift valve. Locate the plug on the end cap for
the load sense, and remove the plug. Install a 1/4” hose from the end cap to the Tiger valve.
Refer to the Parts Section pages for an exploded diagram of the tractor remote valve hookup.

(ASM-JD-0214)