General information – Trane CVHE-SVU01E-ENX39640712050 User Manual

Page 5

Advertising
background image

5

CVHE-SVU01E-EN

An example of a typical model
number is:

CVHF091NAL00ACU2758W7E8TB
C0000000K01G14C10W1A03B1

Model Number Digit Identification

C = (1

st

digit) CenTraVac

®

Hermetic

V = (2

nd

digit) CenTraVac

®

Hermetic

H = (3

rd

digit) Direct Drive

F = (4

th

digit) Development sequence

091 = (5

th

, 6

th

, and 7

th

digit) Nominal

compressor tonnage

N = (8

th

digit) Unit Voltage

A = (9

th

digit) Unit Type

A = Cooling Condenser
B = Heat Recovery Condenser
C = Auxiliary Condenser
D = Free Cooling Option
S = Special

L0 = (10

th

and 11

th

digit) Design

Sequence

0 = (12

th

digit) Hot Gas By-Pass

W = With HGB
0 = Without HGB
S = Special

A = (13

th

) Starter type

A = Star-Delta Unit Mounted
C = Star Delta – Remote Mounted
E = X-Line Full Volt – Remote
Mounted
F = Autotransformer – Remote
Mounted
G = Primary Reactor – Remote
Mounted
H = X-Line Full Volt – Unit Mounted
J = Autotransformer – Unit
Mounted
K = Primary Reactor – Unit
Mounted
L = Solid State – Unit Mounted
M = Solid State – Floor Mounted
N = Solid State – Wall Mounted
P = Adaptive Frequency Drive - Unit
Mounted
R = Customer Supplied

C = (14

th

digit) Control Enclosure

S = Special
C = Standard Control Enclosure

U = (15

th

digit) Compressor Motor

Power (kw)

275 = (16

th

, 17

th

, and 18

th

digit)

Compressor Imp Cutback

8 = (19

th

digit) Evaporator Shell Size

W = (20

th

digit) Evaporator Tube

Bundle

7 = (21

st

digit) Evaporator Tubes

E = (22

nd

digit) Evaporator Waterbox

8 = (23

rd

digit) Condenser Shell Size

T = (24

th

digit) Condenser Tube

Bundle

B = (25

th

digit) Condenser Tubes

C = (26

th

digit) Condenser

Waterboxes

0 = (27

th

digit) Heat Recovery

Condenser Shell Size

0 = (28

th

digit) Heat Recovery

Condenser Tube Bundle

0 = (29

th

digit) Heat Recovery

Condenser Tubes

0 = (30

th

digit) Heat Recovery

Condenser Waterboxes

0 = (31

st

digit) Auxiliary Condenser

Size and Waterboxes

0 = (32

nd

digit) Auxiliary Condenser

Tubes

0 = (33

rd

digit) Orifice Size

K = (34

th

digit) Orifice Size

0 = (35

th

digit) Unit Option

1 = (36

th

digit) Control: Enhanced

protection

G = (37

th

digit) Control: Generic BAS

1 = (38

th

digit) Control: Extended

operation

4 = (39

th

digit) Tracer communication

interface

C = (40

th

digit) Control: Condenser

refrigerant pressure

1 = (41

st

digit) Control: Tracer IO

0 = (42

nd

digit) Special Options

W = (43

nd

digit) Control: Water flow

control

1 = (44

th

digit) Control: Chilled water

reset

A = (45

th

digit) Control: Heat Recovery

temperature sensors

0 = (46

th

digit) Gas Powered Chiller

3 = (47

th

digit) Compressor Motor

Frame Size

B = (48

th

digit) Volute Discharge

Angle

1 = (49

th

digit) Control: Operating

status

W = (50

th

digit) Industrial Chiller

Package (INDP)

0 = Without INDP
W = With INDP

1 = (51

st

digit) Control Power

Transformer (CPTR)

0 = Without CPTR
1 = With CPTR
S = Special

B = (52

nd

digit) Motor and Terminal

Board Configuration

A = Six Lead Low Voltage
B = Three Lead Medium
Voltage
C = Six Lead Medium
Voltage
S = Special

General
Information