3.1.1.1 Selecting PB storage active


• Send command

AT+CPBS=<PB><cr>

where:
<PB> is the desired PB storage:

SM – SIM phonebook
FD – fixed dialing phonebook
LD – last dialed calls list
MC – missed calls list
RC – received calls list

• wait for response:

Response

Reason

Action

OK

selected PB is now active

Proceed ahead

ERROR

some error occurred

Enable extended result codes
(see par. 2.5.2.1)
and retry.

+CME ERROR: 10

SIM not present

Check SIM or require SIM
insertion and repeat from par.
2.5.2.2

+CMS ERROR: 310

SIM not present

Check SIM or require SIM
insertion and repeat from par.
2.5.2.2

+CME ERROR: 11

SIM is present and PIN is
required to continue operations

insert SIM PIN (see par.
2.5.2.3)

+CMS ERROR: 311

SIM is present and PIN is
required to continue operations

insert SIM PIN (see par.
2.5.2.3)

+CME ERROR: 12

SIM is present and PUK is
required to continue operations

insert SIM PUK (see
par.2.5.2.4)

+CMS ERROR: 316

SIM is present and PUK is
required to continue operations

insert SIM PUK (see
par.2.5.2.4)

+CME ERROR: 13

SIM defect

Check SIM insertion or require
a new SIM not defected and
repeat from par. 2.5.2.2

+CMS ERROR: 313

SIM defect

Check SIM insertion or require
a new SIM not defected and
repeat from par. 2.5.2.2

+CME ERROR: 14

SIM is busy

retry later

+CMS ERROR: 314

SIM is busy

retry later

+CME ERROR: 15

SIM is wrong type

Check SIM, it must be a GSM
SIM.


+CMS ERROR: 315


SIM is wrong type


Check SIM, it must be a GSM

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved