GE863-GPS Software User Guide

1vv0300724 Rev. 2 - 24/01/07

3.7.2.2.1 Exit from the alarm status and shutdown


• Send command

AT#SHDN<cr>

• wait for response

OK


At the OK result code, the device will end alarm activity and shutdown.

3.7.2.2.2 Exit from the alarm status and enter the normal operating mode


• Send command

AT#WAKE=0<cr>

• wait for response

OK


At the OK result code, the device will end alarm activity and enter normal operating mode. If the
device was already in normal operating mode (alarm has started when the module was already ON),
then with the command only the alarm activity is terminated.

3.7.2.3 Querying the Alarm status

When the device awakes by means of an alarm time expire, the module starts the alarm activity but
not the network activity, permitting some operations to be done by the controlling application without
registering the mobile in the network.
To check if the mobile is in the "alarm status" and therefore no network activity is done or if the device
is in the normal operating status:

• Send command

AT#WAKE?<cr>

• wait for response in the format:
+WAKE: <status>
OK

where:
<status> is the operating mode:

0 - normal operating mode
1 - alarm mode

NOTE: if the device is in the alarm mode no network activity is done, therefore the only
commands that are accepted are the #WAKE and #SHDN ones.
When in the alarm mode, no operation is allowed towards the network, therefore it is not
possible to receive or send calls, SMS and whatever GSM/GPRS services.

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved