SFI data:
SFI preview:

maximum 7 days in advance

Timer:
Events:

maximum 30 events, one year

in advance

Remote control system:

RC-5

Subsystem address

8 (SAT 1), 10 (SAT 2)

Modulation frequency

36 kHz

Infra-red wavelength

950 nm

Power supply:
Mains power adapter:
Power requirement:
3,0 W

in stand-by mode (clock off)

3,4 W

in stand-by mode (clock on)

10,5 W

in operation, LNC off

18 W

in operation, horizontal polarisa-
tion / 400 mA LNC power

Nominal voltage:
230 V / 50 Hz AC
Input voltage:
180 V.... 250 V / 50 Hz AC
General:
Dimensions (WxDxH):

285 mm x 133 mm x 40 ... 43 mm

Weight:

approx. 490 g

12 Trouble-shooting guide

67

Problem

Possible cause

Solution

Current time not displayed while unit
is in stand-by mode

Time not acquired

Switch to major programme for
approx. 30 secs.

Receiver cannot be switched on, or
cannot be operated

Receiver blocked

Perform Flash Reset: Note! All per-
sonal settings will be lost.
>

Disconnect mains plug.

>

Simultaneously press pro-
gramme up/down key on
receiver
and keep pressed
down.

>

While programme up/down
key is pressed, reconnect
mains plug.

>

Keep keys pressed down for
approx. 5 secs. until message
* “FLAS” appears.