Place the cable control bracket on the floor so that the bracket is 3-5/8” from the front

window. Also the outer rear corner (heel) of the bracket is 5-1/4” from the edge of the
door. The middle corner of the bracket should be 2-1/2” from the edge of the door. See
image below. Be sure that the location of the stand will allow the operation of all control
levers in the tractor and that the door will not strike the stand when shut. Double check
under the cab for cables and wires that may be cut when drilling. And before drilling
double check location of the stand for proper placement of holes. Drill 3 holes to match
control bracket and secure with capscrews and nylock nuts noted in parts section..

The rubber boot under the rear window can be cut in a cross hair pattern and if

necessary the bottom cut through to allow it to slip over the cables and back into position.
These cables will be routed to the lift valve mounted on the valve mounting plate, and
should not have any sharp bends or kinks in them. Secure cables with zip ties and apply
RTV sealer in and around individual cables, inside and outside of the cab for a water tight
seal. Do not allow excess cable to hang unsecured on the outside of the cab.