Vg column description, Figure 3.6.3.1, Name – Thecus Technology i Series User Manual

Page 35: Total(gb), Total capacity of this volume group, Free(gb), Free capacity of this volume group, The number of physical disks of the volume group, Status, The status of volume group

Advertising
background image

Enter “Volume group” to view the status of each volume group.

VG column description:

Figure 3.6.3.1

(Figure 3.6.3.1: There is a RAID 0 with 2 physical disks, named “VG-R0”, total size is
148GB, related to 2 UDV. Another is a RAID 5 with 3 physical disks, named “VG-R5”.)

No.

Number of volume group. The button next to the No. is
“More Information”

indication. It shows the details of

the volume group.

Name

Volume group name. The button next to the Name is
“Rename”

function.

Total(GB)

Total capacity of this volume group.

Free(GB)

Free capacity of this volume group.

#PD

The number of physical disks of the volume group.

#UDV

The number of user data volumes related to the
volume group.

Status

The status of volume group.

“Online”

Æ volume group is online.

“Fail”

Æ volume group is fail.

Status 1

“DG”

Æ DeGraded mode. This volume group is not

completed. The reason could be lack of one disk or
failure of disk.

- 35 -

Advertising