22. Run “Device Manage” in Windows. Make sure MPIO device is

available. Then the disk can be tested performance by IOMETER.


The MC/S setup instructions are very similar to MPIO, detail steps are in the
following figures. For the target side setting, the steps are exactly the same as
MPIO. Please refer to Figure D.1 to Figure D.9.

1. Create a VG.
2. Create a UDV.
3. Run Microsoft iSCSI initiator and check the Initiator Node Name.
4. Attaching LUN to UDV_1 UDV. Input the Initiator Node Name in Host

field.

5. The volume config setting is done.
6. Check iSCSI settings. The IP address of iSCSI data port 1 is

192.168.11.229, port 2 is 192.168.12.229 for example.

7. Add Target Portals on Microsoft iSCSI initiator.
8. Input the IP address of iSCSI data port 1 (192.168.11.229 as

mentioned in previous pages).

Figure D.23

9. Log on.