6. Maintenance and Inspection

Preventive maintenance and inspection is required to maintain the interface in
its optimal condition, and to ensure a long operational lifetime. Depending on
usage and operating conditions, perform a periodic inspection once every three
to six months. Before starting inspections, disconnect all power from the drive.

Inspection Points

Check that the network cable(s) are properly terminated in the terminal
block(s), and ensure that pluggable terminal blocks are fully seated in their
headers. Reseat if necessary.

Check that there are no defects in any attached wire terminal crimp points.
Visually check that the crimp points are not damaged or loose.

Visually check all wiring and cables for damage. Replace as necessary.

Clean off any accumulated dust and dirt.

Do not perform hi-pot tests on the interface, as they may damage the unit.


Please pay close attention to all periodic inspection points and maintain a good
operating environment.

7. Storage and Warranty

7.1 Storage

Observe the following points when the interface is not used immediately after
purchase or when it is not used for an extended period of time.

Avoid storing the unit in places that are hot or humid, or that contain large
quantities of dust or metallic dust. Store the unit in a well-ventilated
location.

When not using the unit for an extended period of time, apply power at
least once every two years and confirm that it still functions properly.

7.2 Warranty

The TOSVERT-300MVi Multiprotocol Ethernet and Modbus RTU Interface is
covered under warranty by Toshiba for a period of 12 months from the date of
installation, but not to exceed 18 months from the date of shipment from the
factory. For further warranty or service information, please contact Toshiba
support.