If installation must be “built in,” the operator must

ensure the following:

†

Minimum of 300 cfm (8.5 cmm) of supplement flow

within the cabinet.

†

Minimum clearances of 2" (51 mm) to every surface.

In addition, the operator will be responsible for com-

pensating any extra time required to service the prod-

uct due to removing the product for serviceability.

Installation Near Open Heat Source (Figure 3)

When placing a TurboChef oven near an open heat

source, strictly adhere to the following:

†

Verify oven location has a minimum 6" (152 mm)

clearance on top and minimum 2" (51 mm) of

clearance on each side.

†

If the oven is being placed near a grill or stove,

there must be a divider between the oven and the

open heat source, with a minimum of 6" (152 mm)

between the oven and the divider.

†

If the oven is being placed near a fryer, there must

be a divider between the oven and fryer, with a

minimum of 12" (305 mm) between the oven and

the divider.

†

The height of the divider must be greater than or

equal to the height of the oven (23"/584 mm).