+(B)

-(C)

(A)

-4800 V

MAGNETRON VOLTAGE

0

-

+

-

+

2400

2400

VDC

4800

VDC

Current

Flow

TRANSFORMER OUTPUT VOLTAGE

+(B)

0

-(C)

(A)

-2400 V

+2400 V

-

-

+

+

2400

VDC

2400

Current

Flow

CAPACITOR CHARGES

ON POSITIVE VOLTAGE SWING

CHARGED CAPACITOR PLUS TRANSFORMER

ON NEGATIVE VOLTAGE SWING

F I G U R E

19: Voltage Doubler Circuit Theory of Operation

VOLTAGE DOUBLER THEORY OF OPERATION

Figure 19

1. The high-voltage transformer steps up the input

voltage to approximately 2400 volts peak (4800

volts peak to peak).

2. The high-voltage capacitor charges to 2400 volts

on the positive going voltage via the high volt-

age diode’s conduction.

3. The high-voltage transformer plus the charged

high-voltage capacitor supply down to -4800

volts to the magnetron when the voltage goes

negative. (high-voltage diode is back biased.)

4. The magnetron converts negative input voltage

(and current) to RF energy at 2450 MHz.

W A R N I N G

: Do not attempt to measure

these voltages.

MICROWAVE SYSTEM PARTS

Figures 20 and 21

11. NGC-3062-1 HV Transformer (2 per oven, 1

per kit) - USA, Mexico, Brazil,

S. Korea

NGC-3062-2 HV Transformer (2 per oven, 1

per kit) - Europe, Asia, Pacific,

Australia, UK, Ireland

NGC-3062-3 HV Transformer (2 per oven, 1

per kit) - Japan

12. NGC-3020 High Voltage Capacitor (2 per

oven, 1 per kit) - USA, Mexico,

Brazil, S. Korea

NGC-3020-2 High Voltage Capacitor (2 per

oven, 1 per kit) - Europe, Asia,

Pacific, Australia, UK, Ireland,

Japan 50 Hz

100207

High Voltage Capacitor (2 per

oven, 1 per kit) - Japan 60 Hz

THE MICROWAVE SYSTEM