USER CONFIGURABLE OPTIONS - ENABLE/DISABLE CODES

The following codes

enable

and

disable

each function/screen listed. They do not take you to the function/screen.

After each code, press

ENTER

. To enable, press 9 after entering code (except

S

-

A

-

V

-

E

,

W

-

A

-

V

-

E

). To disable, press

any key (except 9) after entering code.

Function/Screen

Simultaneously Press

Enter Key Code

Done Screen w/out “Save Time”

BACK

&

ENTER

3-6-6-3 (D-O-N-E)

Done Screen w/ “Save Time” - step 1

BACK

&

ENTER

3-6-6-3 (D-O-N-E)

Done Screen w/ “Save Time” - step 2

BACK

&

ENTER

8-4-6-3 (T-I-M-E)

Edit Recipe Mode

UP

&

DOWN

8-4-3-3 (T-I-D-E)

Load Menu from Card

BACK

&

ENTER

6-3-6-8 (M-E-N-U)

Save Menu to Card - step 1

BACK

&

ENTER

6-3-6-8 (M-E-N-U)

Save Menu to Card - step 2

BACK

&

ENTER

7-2-8-3 (S-A-V-E)

Snooze Screen

BACK

&

ENTER

7-6-6-9 (S-N-O-Z)

Time Screen (Figure 16)

BACK

&

ENTER

8-4-6-3 (T-I-M-E)

Timed Mag Test

BACK

&

ENTER

9-2-8-3 (W-A-V-E)

- Some codes are not available on some ovens.
- Oven must be in Off or Cooling Down mode.

USER CONFIGURABLE OPTIONS - ACCESS CODES

The following codes allow access to each function/screen listed. To enable/disable these codes (where applicable),

see above. After each code, press

ENTER

.

Function/Screen

Simultaneously Press

Enter Key Code

Edit Recipe Mode

UP

&

DOWN

9 (or as specified - see “Set PIN” below)

Erase Menu*

BACK

&

ENTER

3-7-2-7 (E-R-A-S)

Load Menu from Card

Bottom-left, then upper-mid soft key

Master Reset

BACK

&

ENTER

9-4-7-1

Save Menu to Card

Bottom-left, then lower-mid soft key

Set PIN**

UP

&

DOWN

3-3-4-8 (E-D-I-T)

Test Mode

BACK

&

ENTER

9-4-2-8 (W-H-A-T)

Unit Test

BACK

&

ENTER

8-6-4-8 (U-N-I-T)

View Cook Counts

1 & 3

View Faults***

4 & 6

Zero Cook Counts*

BACK

&

ENTER

6-7-3-9 (O-R-E-Z)

- Oven must be in Off or Cooling Down mode.
* To execute, press 3 after entering code.
** Set PIN after entering code. Accessing “Edit Recipe Mode” will now require new PIN instead of 9.
*** To view voltage, press ENTER. To initiate a self test, press the corresponding soft key from the voltage screen.

19

THE CONTROL SYSTEM

Advertising