ISSUE

RESOLUTION

F1: Blower Running

Status Bad

Motor not running

when commanded.

1. Status Indicator “A” is highlighted/backlit in

TEST MODE

.

Verify 208 or 240 (USA) / 230 (Intl) / 200 (Japan) / 220 (Latin America)

VAC is going to the motor controller via pins 2 and 3.

†

208/240/230 VAC is present: Verify control wiring from the motor

controller and I/O control board, specifically low-voltage wire OR-9.

If all wires are OK, then refer to page 50 for motor controller

troubleshooting.

†

208/240/230 VAC is not present: Correct wiring going to the motor

controller. Also, check fuses.

2. Status Indicator “A” is still highlighted in

TEST MODE

.

Refer to page 50 for motor controller troubleshooting.

F3: Magnetron Current

Low

1. Ensure the K2 mechanical relay is in good working order.

If relay is OK, refer to pages 34-35 (

F

3:

MAGNETRON CURRENT LOW

) for

detailed troubleshooting.

F8: Heat Rise Low

N O T E

: This message

occurs in

WARM UP

and

SELF TEST

if the oven fails

to warm up in the prede-

termined time period.

1. Verify the high-limit thermostat is not tripped.

†

If high-limit is tripped, reset and allow the oven to warm up.

†

If high-limit is not tripped, proceed to instructions below.

High-limit thermostat is not tripped:

Check both K4 and K5 SSRs by activating them in

TEST MODE

(activate

HEATER

and

IR ELE

). When actuated, the (-) control input of the SSR will

go to 0.00 VDC. When the relay is not actuated, the input will read

-24.00 VDC.

†

If the control voltage is not pulled down during actuation, verify

the wiring between SSR and I/O control board. Replace SSR if wiring

is OK.

†

If the control voltage is pulled down: Refer to Figure 37 on page 47.