THE MICROWAVE SYSTEM

33

HIGH VOLTAGE TRANSFORMERS

PRIMARY VOLTAGE, FREQ, TAPS,
AND RESISTANCE

SECONDARY TAPS AND
RESISTANCE

NGC-3062-1

208 VAC, 60 Hz, 1 & 2,

0.819–1.001

W

240 VAC, 60 Hz, 1 & 3,

0.972–1.188

W

4, Ground, 53.60–65.52

W

NGC-3062-2

230 VAC, 50 Hz, 1 & 2,

0.972–1.188

W

3, Ground, 57.52–70.30

W

NGC-3062-3

200 VAC, 50/60 Hz, 1 & 2,

0.784–0.958

W

3, Ground, 55.75–68.13

W

FILAMENT TRANSFORMERS

PRIMARY VOLTAGE, FREQ, TAPS,
AND RESISTANCE

SECONDARY TAPS AND
RESISTANCE

NGC-3061-1

208 VAC, 60 Hz, 1 & 2,

17.49–21.37

W

240 VAC, 60 Hz, 1 & 3,

20.61–25.19

W

4, 5, very low resistance - if read-

ing is open, transformer has failed.

NGC-3061-2

230 VAC, 50 Hz, 1 & 2,

18.99–23.21

W

3, 4, very low resistance - if read-

ing is open, transformer has failed.

NGC-3061-3

200 VAC, 50/60 Hz, 1 & 2,

15.70–19.18

W

3, 4, very low resistance - if read-

ing is open, transformer has failed.

HIGH VOLTAGE AND FILAMENT TRANSFORMER RESISTANCE TABLE

How to Check a Capacitor

1. Disconnect the oven from the power source.

2. Fully discharge the capacitor.

3. Isolate the capacitor from the circuit.

4. Connect the ohmmeter between the capacitor

terminals. The ohmmeter should momentarily

indicate a low impedance and then slowly return

to infinite resistance.

5. Reverse the ohmmeter leads and repeat Step 4.

6. Check each terminal to case. Infinite resistance

(open) should be indicated.

How to Check a Magnetron for Open/Shorted Filament

1. Disconnect the AC power source and discharge

the high-voltage capacitors.

2. Isolate the magnetron from the circuit by removing

the wires from the F and FA terminals. Figure 25.

3. An ohmmeter connected between the filament

terminals (F, FA) should indicate a reading of

less than 1 ohm. Figure 25.

4. A continuity check between either filament

terminal and the magnetron chassis should indi-

cate an infinite resistance (open).

How to Check a High-Voltage or Filament Transformer

1. Disconnect the AC power source and discharge

the high-voltage capacitors.

2. Disconnect all the wires in question going to

the transformer.

3. Use an ohmmeter to check the impedance of the

primary and secondary winding. Refer to the

high-voltage and filament transformer table below

to determine if the transformer is OK. If the

resistance is different then the table indicates,

replace the transformer.