TurboChef Technologies TurboChef User Manual

Page 42

Advertising
background image

THE MICROWAVE SYSTEM

32

5. While holding the

MGTRON

soft key, move the sur-

vey meter around the outline of the oven door,

keeping the tip of the meter in contact with and

perpendicular to the oven door. Record the highest

leakage.

6. Using the same procedure, measure the leakage

with the oven door opened to the point just before

the primary and secondary switches disengage.

Record the highest leakage.

T I P

: To hold the oven door open for this

test, back out the top center screw around the

perimeter of the oven door. Continue backing

this screw out until the primary and secondary

interlock switches disengage. As this point, tighten

the screw until both switches re-engage.

7. Using the same procedure, measure the leakage

around the oven’s entire exterior surface. Record the

highest leakage.

HOW TO TEST MICROWAVE COMPONENTS

Testing the High-Voltage Diode

The high-voltage diode (Figure 24) is assembled by

connecting several 1000-1500 volt semiconductor

diodes in a series to increase the reverse voltage capa-

bility. In the circuit, the high-voltage diode conducts

to prevent the filament voltage from becoming posi-

tive, thus as the high-voltage winding of the trans-

former goes to 2400 VPK, the high-voltage capacitor is

charged to 2400 volts. When the high-voltage wind-

ing starts to go toward negative, the high-voltage diode

becomes non-conducting with the charged high-volt-

age capacitor in series with the high-voltage winding.

When the transformer gets to its negative peak of

-2400 VPK, the voltage applied to the filament is

negative 4500 volts.

W A R N I N G

: Never attempt to measure high

voltage directly.

How to Check a Diode

1. Disconnect the oven from the power source.

2. Fully discharge the capacitors.

3. Connect the voltage meter in series with the diode.

4. Using a multimeter set to DC voltage, connect

one meter lead to one side of a 9-volt battery

and the other lead to one side of the diode.

5. Connect the other side of the 9-volt battery to

the other side of the diode. DC voltage should

only be present on the meter in one direction.

6. Switch the meter leads on the diode, which will

cause the opposite reading to be visible.

Depending on the voltage of the battery, voltage

between 5-7 VDC should be present in only one

direction and 0-0.1 VDC in the other direction.

ANTENNA

F

FA

FILAMENT AND

HIGH VOLTAGE

TERMINALS

F I G U R E

24: High Voltage Diode

F I G U R E

25: Magnetron

Advertising