TurboChef Technologies TurboChef User Manual

Page 54

Advertising
background image

ADJUSTING THE SECONDARY AND MONITOR
INTERLOCK SWITCHES - NEW SWITCH SETUP

1. Disconnect power to the unit.

2. Disconnect the 40-pin connector from the I/O

board to allow maximum clearance.

3. Using the 0.060” (1.524 mm) spacer as a

template (included with item 74), adjust the

secondary switch.

NOTE

: This will also adjust the monitor switch.

4. Open and close the door several times to verify

the switch gap.

NOTE

: The absolute maximum gap should not

exceed 0.060” (1.524 mm).

5. Re-connect the 40-Pin connector to the I/O

board and apply power to the unit.

6. Simultaneously press

BACK

and

ENTER

keys.

7. Enter 9-4-2-8, then press

ENTER

.

8. Open the oven door and verify P, S, and M

disengage in sequence.

9. Close the oven door and verify the M, S, and P

engage in sequence.

10.Energize the Microwave System and open the

door.

11.Verify the W indicator is backlit, meaning the

oven microwave system turns OFF when the

door is open.

SECONDARY AND MONITOR SAFETY SWITCH PARTS

Figure 33 and 34

77. 102804

Hinge, Right

78. 102012

Switch, Limit, Micro (x2)

79. NGC-1126 Plate, Door Switch

80. 101914

Standoff, #8-32 F/F x 1”, 5/16”

DIA

81. 101915

Standoff, #8-32 M/F x 5/16”,

1/4” DIA (attached to outside

of Item 80.)

82. 102921

Screw, #8-32 x 3/8”

83. 101558

Screw, 4-40 x 1.125”

F I G U R E

33: Secondary/Monitor Adjustment and Parts -

New Switch Setup

79

80

82

x2

83

x2

78

81 82

77

80

82

81

F I G U R E

34: Secondary/Monitor Switch Assembly -

New Switch Setup

THE OVEN DOOR