CLKREF

Reference

Divider

1

0

CGCR2[RDBYPASS]

PLL

LS

PLLIN

PLLOUT

Output

Divider

0

CGCR4.

[OUTDIVEN]

1

0

CCR2.

[SYSCLKSEL]

LS

SYSCLK

CLKSEL

1

0

CLKIN

RTC Clock

LS

RTC

OSC

RTC_XI

RTC_XO

32.768

KHz

RTC_CLKOUT

RTC

1

(

)

M + 4

CLKREF

RDRATIO + 4

´

(

)

M + 4

1

CLKREF

RDRATIO + 4

ODRATIO + 1

´

´

CLKREF

M + 4

´ й

щ

л

ы

1

CLKREF

M + 4

ODRATIO + 1

´

´

й

щ

л

ы

System Clock Generator

www.ti.com

Figure 1-4. Clock Generator

1.4.2 Functional Description

The following sections describe the multiplier and dividers of the clock generator.

1.4.2.1

Multiplier and Dividers

The clock generator has a one multiplier and a two programmable dividers: one before the PLL input and
one on the PLL output. The PLL can be programmed to multiply the PLL input clock, PLLIN, using a x4 to
x4099 multiplier value. The reference clock divider can be programmed to divide the clock generator input
clock from a /4 to /4099 divider ratio and may be bypassed. The Reference Divider and RDBYPASS mux
must be programmed such that the PLLIN frequency range is 32.786 KHz to 170 KHz. At the output of the
PLL, the output divider can be used to divide the PLL output clock, PLLOUT, from a /1 to a /128 divider
ratio and may also be bypassed. The PLL output, PLLOUT, frequency must be programmed within the
range of at least 60 MHz and no more than the maximum operating frequency defined by the datasheet,
Fsysclk_max parameter. See

Table 1-10

for allowed values of PLLIN, PLLOUT, and SYSCLK. Keep in

mind that programming the output divider with an odd divisor value other than 1 will result in a non-50%
duty cycle SYSCLK. This is not a problem for any of the on-chip logic, but the non-50% duty cycle will be
visible on chip pins such as EM_SDCLK (in full-rate mode) and CLKOUT. See

Table 1-10

for allowed

values of PLLIN, PLLOUT, and SYSCLK.

The multiplier and divider ratios are controlled through the PLL control registers. The M bits define the
multiplier rate. The RDRATIO and ODRATIO bits define the divide ratio of the reference divider and
programmable output divider, respectively. The RDBYPASS and OUTDIVEN bits are used to enable or
bypass the dividers.

Table 1-5

lists the formulas for the output frequency based on the setting of these

bits.

The clock generator must be placed in BYPASS MODE when any PLL dividers or multipliers are changed.
Then, it must remain in BYPASS MODE for at least 4 mS before switching to PLL MODE.

Table 1-5. PLL Output Frequency Configuration

RDBYPASS

OUTDIVEN

SYSCLK Frequency

0

0

0

1

1

0

1

1

1.4.2.2

Powering Down and Powering Up the System PLL

To save power, you can put the PLL in its power down mode. You can power down the PLL by setting the
PLL_PWRDN = 1 in the clock generator control register CGCR1. However, before powering down the
PLL, you must first place the clock generator in bypass mode.

24

System Control

SPRUFX5A – October 2010 – Revised November 2010

Submit Documentation Feedback

Copyright © 2010, Texas Instruments Incorporated

Advertising