2 rtc interrupt flag register (rtcintfl) [1920h – Texas Instruments TMS3320C5515 User Manual

Page 47

Advertising
background image

www.ti.com

Power Management

1.5.4.2

RTC Interrupt Flag Register (RTCINTFL) [1920h]

The RTC interrupt flag register (RTCINTFL) is shown in

Figure 1-19

and described in

Table 1-29

.

Figure 1-19. RTC Interrupt Flag Register (RTCINTFL) [1920h]

15

14

8

ALARMFL

Reserved

R-0

R-0

7

6

5

4

3

2

1

0

Reserved

EXTFL

DAYFL

HOURFL

MINFL

SECFL

MSFL

R-0

R-0

R-0

R-0

R-0

R-0

R-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 1-29. RTC Interrupt Flag Register (RTCINTFL) Field Descriptions

Bit

Field

Value

Description

15

ALARMFL

Indicates that an alarm interrupt has been generated.

0

Alarm interrupt did not occur.

1

Alarm interrupt occurred (write 1 to clear).

14-6

Reserved

0

Reserved.

5

EXTFL

External event (WAKEUP pin assertion) has occurred.

0

External event interrupt has not occurred.

1

External event interrupt occurred (write 1 to clear).

4

DAYFL

Day event has occurred.

0

Periodic Day event has not occurred.

1

Periodic Day event occurred (write 1 to clear).

3

HOURFL

Hour event has occurred.

0

Periodic Hour event has not occurred.

1

Periodic Hour event occurred (write 1 to clear).

2

MINFL

Minute Event has occurred.

0

Periodic Minute event has not occurred.

1

Periodic Minute event occurred (write 1 to clear).

1

SECFL

Second Event occurred.

0

Periodic Second event has not occurred.

1

Periodic Second event occurred (write 1 to clear).

0

MSFL

Millisecond event occurred.

0

Periodic Millisecond event has not occurred.

1

Periodic Millisecond event occurred (write 1 to clear).

47

SPRUFX5A – October 2010 – Revised November 2010

System Control

Submit Documentation Feedback

Copyright © 2010, Texas Instruments Incorporated

Advertising